Features and Benefits
- Easy to use
- Effective expansion properties
- Reduces the internal pressures created in cast-in-place applications
Applications
- Swellstop is installed in and along the joint after the first concrete pour and just before the second pour
LIMITATIONS, CONSIDERATIONS AND PRECAUTIONS:
- Swellstop should be used in below grade, non-moving joints only and is not appropriate for expansion joint applications
- Cracking and/or spalling of the concrete can be caused by the expansion pressure of Swellstop. A minimum 5cm of concrete coverage is recommended. Increase this coverage if using lightweight or low strength concrete (<3500 PSI compressive strength)
- Swellstop required the presence of moisture to initiate and maintain expansion. The expansion process begins immediately when Swellstop contacts water
- Swellstop Primer Adhesive and Swellstop Waterstop should be applied on the same day
- Inspect Swellstop for premature swell, discontinuity, and debris contamination immediately prior to the 2nd concrete pour. If swelling and/or damage has occurred, remove and replace the material with new
- Do not remove separation paper from Swellstop until just prior to the 2nd concrete pour
- Store material in a cool, dark, dry environment