Features and Benefits

  • Easy to use
  • Effective expansion properties
  • Reduces the internal pressures created in cast-in-place applications

Applications

  • Swellstop is installed in and along the joint after the first concrete pour and just before the second pour

‍       LIMITATIONS, CONSIDERATIONS AND PRECAUTIONS:

  • Swellstop should be used in below grade, non-moving joints only and is not appropriate for expansion joint applications
  • Cracking and/or spalling of the concrete can be caused by the expansion pressure of Swellstop. A minimum 5cm of concrete coverage is recommended. Increase this coverage if using lightweight or low strength concrete (<3500 PSI compressive strength)
  • Swellstop required the presence of moisture to initiate and maintain expansion. The expansion process begins immediately when Swellstop contacts water
  • Swellstop Primer Adhesive and Swellstop Waterstop should be applied on the same day
  • Inspect Swellstop for premature swell, discontinuity, and debris contamination immediately prior to the 2nd concrete pour. If swelling and/or damage has occurred, remove and replace the material with new
  • Do not remove separation paper from Swellstop until just prior to the 2nd concrete pour
  • Store material in a cool, dark, dry environment

Category

Product Resources

Product Brochure